EA-09-103 · CAL · Issued 2009-07-10 · Reactor Licensees
Action
EA Number
EA-09-103
Licensee
NOV (White)
Category
Reactor Licensees
Action type
CAL
Date issued
2009-07-10
Description
On July 10, 2009, the NRC issued a Notice of Violation to Southern Nuclear Operating Company, Inc. (SNC) for a violation of 10 CFR 50.54(q) which states, in part, that the licensee shall follow and maintain emergency response plans which must meet planning standards in 10 CFR 50.47(b). 10 CFR 50.47(b) requires, in part, that the licensee establish a means to provide early notification and clear instruction to the populace within the plume exposure pathway Emergency Planning Zone (EPZ). SNC emergency plan identifies both tone alert radios (TARs) and sirens as the means by which it provides alert and notification to the populace within the plume exposure pathway. This violation is associated with a White Significance Determination Process finding. Specifically, in January 2008, the licensee identified that approximately 109 TARs had not been provided to residences that were outside the limits of the sirens but within the 10 mile EPZ of Farley Nuclear Plant. The licensee's subsequent review identified additional residences within the 10 mile EPZ which were required to have TARs in accordance with the Farley emergency plan, but were not provided TARs.